|
|

|

|

-
Services
-
InDemand Home Inspections, Inc. provides a long list of inspection services for your home. Our inspections are very thorough and dependable. Our professional staff will make sure every facet of your home is inspected from the interior to the exterior. We look forward to serving all your home inspection needs.
Please browse the sections below for a selected list of the areas we provide inspection services for.
Call Us Today For More Information!
(586) 296-0556
Quality Inspections... Every Time... No Excuses
| |
 |
|




|

|
-

Structural Components

-
The Inspector shall observe structural components, including:
- Foundations
- Floors
- Walls
- Columns
- Ceilings
- Roofs
The Inspector shall describe the type of:
- Foundation
- Floor structure
- Wall structure
- Columns
- Ceiling structure
- Roof structure.



|
| |
 |
|


|

|
-

Exterior

-
The Inspector shall observe:
- Wall cladding, flashings and trim
- Entryway doors and representative number of windows
- Garage door operators
- Decks, balconies, stoops, steps, areaway and porches, including railings
- Eaves, soffits and fascias
- Vegetation, grading drainage, driveways, patios, walkways and retaining walls with respect to their effect on the condition of the building



|
| |
 |
|


|

|
-

Roofing

-
The Inspector shall observe:
- Roof coverings
- Roof drainage systems
- Flashing
- Skylights
- Chimneys
- Room penetrations
Signs of leaks or abnormal condensation on building components will also be observed.



|
| |
 |
|
| |
 |
|


|

|
-

Electrical

-
The Inspector shall observe:
- Service entrance conductors
- Service equipment, grounding equipment, main over current device, main and distribution panels
- Amperage and voltage ratings of the service
- Branch circuit conductors, their over current devices, and the compatibility of their ampacities and voltage
- The operation of a representative number of installed lighting fixtures, switches and receptacles located inside the house, garage and on it’s exterior walls
- The polarity and grounding of all receptacles within six feet of interior plumbing fixtures, and all receptacles in the garage or carport and on the exterior of inspected structures.
- The operation of ground fault circuit interrupters
The Inspector shall describe:
- Service amperage and voltage
- Service entry conductor materials
- Service type as being overhead or underground
- Location of main and distribution panels



|
| |
 |
|


|

|
-

Heating

-
The Inspector shall observe:
- Heating equipment
- Normal operating controls
- Automatic safety controls
- Chimneys, flues and vents
- Solid fuel heating devices
- Heat distribution systems including fans, pumps, ducts and piping with supports, dampers, insulation, air filters, registers, radiators, fan-coil units convectors
- The presence of an installed heat source in each room
The Inspector shall observe:
- Energy source
- Heating equipment and distribution type



|
| |
 |
|


|

|
-

Central Air-Conditioning

-
The Inspector shall observe:
- Central air conditioning
- Normal operating controls
- Cooling and air conditioning equipment
The Inspector shall also observe:
- Distribution systems
- Fans
- Pumps
- Ducts
- Piping with supports
- Dampers insulation
- Air filters
- Registers
- Fan-coil units
The inspection also includes the presence of an installed cooling source in each room.



|
| |
 |
|


|

|
-

Interiors

-
The Inspector shall observe:
- Walls, ceilings and floors
- Steps, stairways, balconies and railings
- Counters and a representative number of cabinets
- A representative number of doors and windows
- Separation walls, ceilings and doors between a dwelling unit and an attached garage or another dwelling unit.
- Sumps
The Inspector shall:
- Operate a representative number of primary windows and interior doors
- Report signs of water penetration into the building or signs of abnormal or harmful condensation on building components



|
| |
 |
|


|

|
-

Insulation and Ventilation

-
The Inspector shall observe:
- Insulation and vapor retarders in unfinished spaces
- Ventilation of attics and foundation areas
- Kitchen, bathroom and laundry venting systems
The Inspector shall describe:
- Insulation and vapor retarders in unfinished spaces
- Absence of same in unfinished space at conditioned surfaces



|
| |
 |
|


|

|
-

General Safety

-
The inspector shall observe:
- Smoke detectors
- Carbon monoxide detectors
- Cooking ventilation
- Fence and gate
- Child safety
- Clothes dryer vent
Built in Appliance
- Cook top
- Oven
- Dishwasher
- In sink disposal



|
| |
 |
|


|

|
-

Pool and Hot Tub Inspection

-
We Observe:
- General overall construction
- Plumbing
- Safety railing and fence
- Filter and pump installation
- Grounding of fixtures
- Grounding of electrical systems
- Lighting in the pool or spa
- GFI protection
- Door and fence alarms
- Drainage systems around walk area
- Fill and empty systems
- Visible leaks or cracks
- Heater operation and venting safety valves



|
| |
 |
|
| |
 |
|
|

|